26xx Technical Manual EN-V108
56
3.4.6 Phone Setting
Primary Ringing
Ringing Frequency Specify the Ringing frequency value.
ringing frequency : 15~100 (Unit : Hz)
Ringing ON Specify the Ringing ON value.
ringing ring ON : 0~8000 (Unit : ms)
Ringing OFF Specify the Ringing OFF value.
ringing ring OFF : 0~8000 (Unit : ms)
Ringing level Specify the ringing level.
ringing level : 0 ~ 94 (Unit : V)
Flash low Specify the value of the flash (low).
: 60~2000 (Unit : ms).
If the phone-set’s flash time is smaller
than the Flash Low setting, the flash
will be ignored.
Flash high Specify the value of the flash (high).
: 60~2000 (Unit : ms)
If the phone-set’s flash time is larger
Vista de pagina 56